[Jan-2022] NS0-176 Braindumps – NS0-176 Questions to Get Better Grades
NS0-176 Exam Dumps - Try Best NS0-176 Exam Questions - PracticeDump
NetApp NS0-176 Exam Topics:
| Section | Objectives |
|---|---|
| FlexPod Configuration | - Describe how to install and configure the FlexPod components - Describe how to configure neworks in a UCS solution - Describe how to configure SAN boot in a FlexPod solution - Describe knowledge of how to configure a service profile - Demonstrate knowledge of how to configure storage in a FlexPod solution - Demonstrate knowledge of how to configure Cisco Nexus switches |
| Information Gathering for FlexPod Solutions | - Describe the main FlexPod components |
| FlexPod Troubleshooting | - Demonstrate how to perform FlexPod troubleshooting |
| FlexPod Design | - Describe the storage components supported in FlexPod - Describe the networking components supported in FlexPod - Describe the compute components supported in FlexPod |
| FlexPod Administration | - Demonstrate knowledge of how to administer FlexPod solutions according to FlexPod best practices - Describe FlexPod management applications - Demonstrate knowledge of how to install and upgrade the FlexPod solution |
NetApp NS0-176 Exam Certification Details:
| Exam Registration | PEARSON VUE |
| Exam Code | NS0-176 FlexPod |
| Exam Name | Cisco and NetApp FlexPod Implementation and Administration |
| Sample Questions | NetApp NS0-176 Sample Questions |
| Passing Score | 68% |
| Duration | 60 minutes |
| Number of Questions | 60 |
| Exam Price | $150 USD |
NEW QUESTION 15
Click the Exhibit button.
On your NetApp storage system, you create a volume named datastore1, mount it to a junction path, and then set the correct export policy. When you attempt to mount the volume from VMware ESXi as a datastore, the server is unable to mount the path /datastore1. You verify that your existing NFS datastore (/datastore0) on the same NetApp storage system SVMis functioning normally.
Referring to the exhibit, what is preventing the server from mounting the new datastore?
- A. The LIF needs to be at its home-port when the volume is mounted.
- B. The load-sharing mirrors need to be updated.
- C. The volume is too large to be mounted as an NFS datastore
- D. Two volumes cannot be mounted using the same LIF IP address.
Answer: B
NEW QUESTION 16
How many cluster interconnect switch(es) are required for a 4-node NetApp cluster?
- A. 0
- B. 1
- C. 2
- D. 3
- E. 4
Answer: D
NEW QUESTION 17
Your customer has the storage configuration for a FlexPod solution shown below.
- FAS8040 HA-pair
- Disk stack one-4x DS4243 disk shelves (2TB SATA disk drives)
- Disk stack two- 2x DS 2246 disk shelves (1.2TB disk drives)
- There are no unused SAS ports on either controller
- There are no expansion slots available on either controller
The customer wants to attach a single DS2246 disk shelf with 800 GB SSD drives.
In this scenario, what are two ways to connect the new shelf for optimal performance? (Choose two).
- A. Cable a new stack for the SSD shelf.
- B. Cable the new shelf to the end of stack two.
- C. Cable the new shelf to the beginning of stack two.
- D. Cable the new shelf to the end of stack one.
Answer: A,C
NEW QUESTION 18
When installing an instance of VMware ESXi on a UCS B-Series server, where should an ISO image be loaded?
- A. Only physical install disks are supported on UCS B-Series servers
- B. The UCS vCenter Plugin must be used
- C. ISO images should not be used
- D. From the UCS Manager select KVM Console, Select the Virtual Media tab, and select Add Image
Answer: D
NEW QUESTION 19
You have a NetApp clustered Data ONTAP storage system and vSphere 6 cluster. You discover that VMware VAAI for NFS is not showing as enabled on one of the five ESXi hosts in your vSphere cluster.
In this scenario, what must you do to enable VAAI for NFS on that ESXi host?
- A. Enable NFSv3 on the storage system.
- B. Set the DataMover. HardwareAcceleratedInit advanced setting to 0 on the ESXi host.
- C. Install the NetApp NFS Plug-in for VMware VAAI on the ESXi host.
- D. Enable VMware vStorage for NFS on the NetApp SVM.
Answer: A
NEW QUESTION 20
Your UCS environment has recently been upgraded to include UCS B-Series Servers, UCS C-Series Servers, a UCS mini, and a fourth UCS domain. With these new changes, you need a management tool to help you manage the entire environment from a single location.
In this scenario, which tool would you use?
- A. Cisco Smart Advisor
- B. UCS Manager
- C. UCS Director
- D. UCS Central
Answer: D
NEW QUESTION 21
Exhibit:
Which hardware component is shown in the exhibit?
- A. IOM
- B. GEM
- C. Fl
- D. VIC
Answer: A
NEW QUESTION 22
NetApp recommends that your SSL key length be?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
NEW QUESTION 23
Exhibit:
An iSCSI SAN boot is not working for a new Cisoc UCS service profile. The new vNIC template was created using the settings shown in the exhibit.
What should you do to make iSCSI SAN boot work?
- A. Change the MAC pool to "<not set>".
- B. Specify a QoS policy.
- C. Set the iSCSI-A-VLAN as the "Native VLAN".
- D. Change the vNIC template to type "Initial Template".
Answer: B
NEW QUESTION 24
Exhibit:
An administrator is configuring a NetApp 8-node AFF8060 system as part of a FlexPod solution and will be cabling the system based on the recommended guidelines shown in the exhibit.
Based on this information, which switch would be used for the cluster interconnect connections?
- A. NetApp CN1610
- B. Nexus 5596
- C. Nexus 5548
- D. NetApp CN1601
Answer: A
NEW QUESTION 25
Which set of commands maps VLAN 100 to VSAN 100?
- A. Nexus 5000-A#configure terminal Nexus 5000-A (config) # vlan 100 Nexus 5000- A (config-vlan_ #fcoe vsan 100
- B. Nexus 5000-B# configure terminal Nexus 5000-B (config) # vsan database Nexus 5000-B (config-vsan)# vsan 100 Nexus 5000-B(config- vsan) #vsan 100 name FCoE-VLAN 100
- C. Nexus 5000-B# configure terminal Nexus 5000-B(config-vsan) # vlan 100 Nexus 5000-B (config-vsan)# vsan 100 name vsan100
- D. Nexus 5000-A#configure terminal Nexus 5000-B (config) # vsan database Nexus 5000-A (config)# vsan 100 Nexus 5000-A (config-vsan) # fcoe vsan 100
Answer: A
NEW QUESTION 26
How are jumbo frames enabled on the Nexus 5548?
- A. system qosmtu 9216
- B. policy-map type queueingclass type queueing class-defaultmtu 9216
- C. system jumbo-frame
- D. system mtu jumbo 9000
- E. policy-map type network-qos JUMBOclass type network-qos class-defaultmtu 9216system qosservice-policy type network-qos JUMBO
Answer: E
NEW QUESTION 27
A customer wants a newly deployed UCS C-Series server's fans to run at the minimum speed required to keep the server cool. The customer is also complaining that the server fans are making too much noise.
In this scenario, which type of fan speed should you select under the Power Control Policy of UCSM?
- A. Balanced
- B. Performance
- C. Low Power
- D. Max Power
Answer: A
NEW QUESTION 28
You have a FlexPod solution with Cisco 6296UP Fabric Interconnects. You currently have a direct-attached AFF8040 system using FCoE for storage connectivity. You would like to reconfigure the FlexPod so that the storage is connected through the upstream switches.
Using UCS Manager, which two steps would you perform to accomplish this task? (Choose two.)
- A. Using the Configure Unified Ports wizard, change the port types to Ethernet.
- B. Using the Configure Unified Ports wizard, change the port types to FC.
- C. Configure the FI ports with the FCoE Uplink role.
- D. Configure the FI ports with the Uplink role.
Answer: B,D
NEW QUESTION 29
What determines the size of the .vswap file for a VMware VM?
- A. the total amount of RAM used by the ESXi host
- B. the size of the RAM plus the log file
- C. the RAM assigned to the VM
- D. the amount of RAM assigned to the VM minus the amount of RAM reserved
Answer: D
NEW QUESTION 30
......
Verified NS0-176 exam dumps Q&As with Correct 141 Questions and Answers: https://www.practicedump.com/NS0-176_actualtests.html
Get New NS0-176 Certification – Valid Exam Dumps Questions: https://drive.google.com/open?id=1AwEgAdjSilZvNIPx8iFlqJLgvGzrWsyn