Read Online 350-601 Test Practice Test Questions Exam Dumps [Q199-Q221]

Share

Read Online 350-601 Test Practice Test Questions Exam Dumps

Easily To Pass New 350-601 Premium Exam Updated [Mar 23, 2025]


Cisco 350-601 certification exam is a comprehensive test that covers a wide range of topics, including network design, storage networking, compute, automation, and security. 350-601 exam also includes hands-on lab exercises that evaluate the candidate's ability to implement and troubleshoot complex data center solutions. Passing 350-601 exam requires a deep understanding of data center technologies and their practical applications.

 

NEW QUESTION # 199
Refer to the exhibit.

Which command is run from the Guest Shell to set the description on the first five interfaces of the Cisco Nexus switch?

  • A. Option A
  • B. Option B
  • C. Option D
  • D. Option C

Answer: C

Explanation:
NXs1# guestshell
[admin@guestshell ~]$ for x in {1..5}; do dohost "conf t ; interface eth1/$x ; description Server$x" ; done Enter configuration commands, one per line. End with CNTL/Z.
Enter configuration commands, one per line. End with CNTL/Z.
Enter configuration commands, one per line. End with CNTL/Z.
Enter configuration commands, one per line. End with CNTL/Z.
Enter configuration commands, one per line. End with CNTL/Z.
[admin@guestshell ~]$


NEW QUESTION # 200
Refer to the exhibit.

What is the result of implementing this configuration?

  • A. The switch queries the TACACS+ server by using an encrypted text PAP login.
  • B. The switch queries the TACACS+ server by using a clear text PAP login.
  • C. The timeout value on the TACACS+ server is 10 seconds.
  • D. The TACACS+ server uses the type-6 encrypted format.

Answer: C


NEW QUESTION # 201
When a strict CoPP policy is implemented, which statement describes an event during which packets are dropped?

  • A. A large system image is copied to a switch by using the default VRF.
  • B. A ping sweep is performed on a network that is connected through a switch.
  • C. Fifteen SSH sessions remain connected to the switch.
  • D. A web server that is connected to a switch is affected by a DDoS attack.

Answer: D

Explanation:
Section: Security


NEW QUESTION # 202
An engineer is seeking the most optimal on demand CPU performance while configuring the BIOS settings of a UCS C-series rack mount server.
What setting will accomplish this goal?

  • A. C2 state
  • B. C0/C1 state
  • C. C6 non-Retention
  • D. C6 Retention

Answer: D

Explanation:
Section: Compute


NEW QUESTION # 203
A POAP-enabled Cisco Nexus switch will not enter POAP mode. Which two conditions should be verified?
(Choose two.)

  • A. The license file is missing on the switch.
  • B. No Cisco NX-OS image is present on the bootflash.
  • C. No startup configuration is available.
  • D. The switch is in bootup process.
  • E. Bootflash must contain a special directory named POAP with poap.py file.

Answer: A,E


NEW QUESTION # 204
A customer has a requirement to deploy a cloud service and needs to have full control over the underlying OS, data and applications.
Which cloud model meets this requirement?

  • A. PaaS
  • B. MaaS
  • C. SaaS
  • D. IaaS

Answer: D

Explanation:
Section: Network


NEW QUESTION # 205
An engineer must configure two Cisco Nexus 7000 series switches in the same data center to support OTV.
Which command set completes the join interface configuration?

  • A. Option D
  • B. Option A
  • C. Option B
  • D. Option C

Answer: B


NEW QUESTION # 206
Refer to the exhibit.

What is configured as a result of running these commands?

  • A. loose unicast RPF
  • B. reverse lookup for outbound packets
  • C. strict unicast RPF
  • D. IP Source Guard

Answer: C

Explanation:
https://tools.cisco.com/security/center/resources/unicast_reverse_path_forwarding The ip verify unicast source reachable-via rx command enables Unicast RPF in strict mode. To enable loose mode, administrators can use the any option to enforce the requirement that the source IP address for a packet must appear in the routing table.


NEW QUESTION # 207
An engineer must configure a named VSAN when the fabric interconnect is in Fibre Channel switch mode The VSAN must meet these requirements:
* Named VSAN must be called "VSAN 10".
* VSAN ID must be 10.
* FCoE ID must be 20.
* VSAN 10 must be attached to port 2 in slot 1.
Which command set configures a VSAN when the fabric interconnect is in Fibre Channel switch mode?

  • A. Option D
  • B. Option A
  • C. Option B
  • D. Option C

Answer: B


NEW QUESTION # 208
Which configuration generates a syslog message when CPU utilization is higher than 60%?

  • A. event manager applet HIGH-CPU
    event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type next entry-op lt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high"
  • B. event manager applet HIGH-CPU
    event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op gt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high"
  • C. event manager applet HIGH-CPU
    event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op lt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high"
  • D. event manager applet HIGH-CPU
    event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type next entry-op gt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high"

Answer: B

Explanation:
The correct configuration to generate a syslog message when CPU utilization is higher than 60% is option A.
This configuration uses the Event Manager Applet feature of Cisco IOS to monitor the CPU utilization via SNMP. When the CPU utilization exceeds 60%, the specified action is triggered, which in this case is to send a syslog message with a priority of notifications and the message "cpu high". The event snmp oid command specifies the OID to be monitored, and the entry-op gt 60 part of the command sets the condition for triggering the action when the value is greater than 60. The poll-interval 5 specifies that the SNMP OID will be polled every 5 seconds.
https://www.cisco.com/c/en/us/support/docs/ip/internet-protocol-ip/200931-EEM-Subsystem-in-Order-to- Monitor-CPU-Tr.pdf
https://blog.ipspace.net/2008/06/generate-snmp-trap-on-high-cpu-load.html


NEW QUESTION # 209
Refer to the exhibit.

An engineer is configuring a VSAN on the network Which option must be selected to create the VSAN?

  • A. FC Zoning Enabled
  • B. Common/Global
  • C. Fabric A
  • D. Fabric B

Answer: C

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/nx-os/configuration/guides/fabric/fabric
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-central/GUI-User-Guides/Storage-Mgmt/1-5/


NEW QUESTION # 210
Refer to the exhibit.

Which two statements describe the routing table of the leaf switch? (Choose two.)

  • A. The next hop 10.0.1.14 for route 172.16.99.0/24 is the TEP address of a border leaf in ACI.
  • B. 172.16.100.0/24 is a BD subnet in ACI.
  • C. The next hop 10.0.8.65 for route 10.20.1.0724 is the TEP address of a border leaf in ACI.
  • D. The next hop 10.1.168.95 for route 172.16.100 0/24 is the TEP address of a border leaf in ACI.
  • E. 10.20.1.0/24 is a BD subnet in ACI.

Answer: A,E


NEW QUESTION # 211
An engineer is implementing NPV mode on a Cisco MDS 9000 Series Switch. Which action must be taken?

  • A. All switches in the fabric must be Cisco MDS switches.
  • B. The FCNS database must be disabled in the fabric.
  • C. A port channel must be configured to the upstream switch.
  • D. NPIV must be enabled on the upstream switch.

Answer: D

Explanation:
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/5_0/configuration/guides/int/nxos/cli_in


NEW QUESTION # 212

Refer to the exhibit. Which command needs to be added to the line starting with the "file" keyword to have the generated running-config file with the name 'fusion-config_' and current date?

  • A. str.('fusion-config_') + date
  • B. ('fusion-config_ + date')
  • C. ('fusion-config_') + date
  • D. string(('fusion-config_') + date

Answer: A

Explanation:
Section: Automation


NEW QUESTION # 213
A network engineer must perform a backup and restore of the Cisco Nexus 5000 Series Switch configuration. The backup must be made to an external backup server. The only protocol permitted between the Cisco Nexus Series switch and the backup server is UDP. The backup must be used when the current working configuration of the switch gets corrupted. Which set of steps must be taken to meet these requirements?

  • A. 1. Perform a startup-config backup to a TFTP server. 2. Copy backup-config from the backup server to the running-config file.
  • B. 1. Perform a startup-config backup to an FTP server. 2. Copy startup-config in the boot flash to the running-config file.
  • C. 1. Perform a running-config backup to an SFTP server. 2. Copy backup-config from the SFTP server to the running-config file.
  • D. 1. Perform a running-config backup to an SCP server. 2. Copy running-config in the boot flash to the running-config file.

Answer: A

Explanation:
TFTP runs on UDP 69 = Is correct


NEW QUESTION # 214
Which MAC address is an HSRP version 2?

  • A. 0100.5E7F.FFFF
  • B. 3799.9943 3000
  • C. 0000.OC07.AC1H
  • D. 0000.0C9F.F0C8

Answer: C


NEW QUESTION # 215
What is a feature of NFS?

  • A. zone-based access control
  • B. block-based file access
  • C. role-based access control
  • D. Kerberos-based security model

Answer: D

Explanation:
https://www.cisco.com/c/en/us/support/docs/security-vpn/kerberos/16087-1.html#modifiednfs


NEW QUESTION # 216
An engineer requires the Cisco Fabric Services to distribute NTP configuration only to the members within the scope of a VSAN that belongs to a Cisco Unified Network. Which scope distribution must be selected to meet this requirement?

  • A. Physical scope
  • B. Uncoordinated scope
  • C. Logical scope
  • D. Coordinated scope

Answer: C

Explanation:
Cisco Fabric Services (CFS) offers a logical scope distribution mode that allows configurations to be distributed within the scope of a VSAN. This mode is suitable for features like NTP, where the configuration database is applicable only within a VSAN. It ensures that changes are contained within the specific VSAN, preventing any impact on other VSANs in the network.
References:
* Cisco's official documentation on Configuring and Managing VSANs1 provides a detailed explanation of VSANs, their advantages, and how they can be managed using CFS.
* The Cisco Fabric Services guide2 further elaborates on the features of CFS, including the logical scope distribution mode and its relevance to features like NTP.
* Community discussions on NTP configuration3 can also provide practical insights into the application of these settings in real-world scenarios.


NEW QUESTION # 217
An engineer requires a solution to automate the configuration and deployment of remote network devices for a customer. The engineer must keep these considerations in mind:
* The customer's environment is based on industry-accepted standards and requires a solution that meets these standards.
* The security requirements mandate the use of a secure transport mechanism between the automation software and target devices such as SSH or TLS.
* The solution must be based on a human-readable and easy to parse format such as XML or JSON.
Which solution must be used to meet these requirements?

  • A. SNMP
  • B. NETCONF
  • C. Ansible
  • D. REST API

Answer: B

Explanation:
https://www.cisco.com/c/en/us/products/collateral/ios-nx-os-software/ios-xe/nb-06-cisco-ios-xe-faq-en.html


NEW QUESTION # 218
A customer has a requirement for an automation solution that supports periodically acquiring configuration from a centralized server and aligning UCS servers to their desired state.
Which open-source tool meets this requirement?

  • A. SaltStack
  • B. Puppet
  • C. Terraform
  • D. Kubernetes

Answer: B


NEW QUESTION # 219
Which NFS version uses the TCP protocol and needs only one IP port to run the service?

  • A. NFSv3
  • B. NFSv1
  • C. NFSv2
  • D. NFSv4

Answer: D

Explanation:
NFSv4 uses the TCP protocol and requires only one IP port (2049) to run the service. This simplifies firewall configuration and improves security by reducing the number of open ports


NEW QUESTION # 220
An engineer must configure remote authentication on a Cisco UCS system. The user password must be encrypted before it is sent to the authentication server. The company security policy requires the server to be based on an open standard. Drag and drop the UCS CLI AAA configuration commands from the left into the order in which they must be implemented on the right. Not all commands are used.

Answer:

Explanation:

Explanation:
UCS-A# scope security
UCS-A /security # scope radius
UCS-A /security/radius # create server radiusserv7
UCS-A /security/radius/server* # set key
UCS-A /security/radius/server* # commit-buffer


NEW QUESTION # 221
......


Cisco DCCOR 350-601 Practice Test Questions, Cisco DCCOR 350-601 Exam Practice Test Questions

Successfully completing the Cisco 350-601 DCCOR: Implementing Cisco Data Center Core Technologies exam makes you eligible for the following certifications: CCIE Data Center, CCNP Data Center, and Cisco Certified Specialist – Data Center Core.

 

350-601 Certification All-in-One Exam Guide Mar-2025: https://www.practicedump.com/350-601_actualtests.html

Get Real 350-601 Exam Dumps [Mar-2025] Practice Tests: https://drive.google.com/open?id=1TgkGyt6TCylxlnzZyS-tgANu1r1gq99g